Skip to content
Visit us at Harrisburg Fire Expo May 17th & 18th 2024
Visit us at Harrisburg Fire Expo May 17th & 18th 2024

Station Alert 812 System (SA812) Controller Kit

Original price $299.95 - Original price $299.95
Original price
$299.95
$299.95 - $299.95
Current price $299.95

SA812 Station Alert Controller Kit Includes:
SA812 Controller
12VDC 5 Amp Power Supply
5-Pin DIN Pager Motorola & Unication Pager Link Cable
User Manual

The Station Alert SA812 Controller is designed to be connected directly to a Unication G Series or Motorola Minitor Amplified Charger. It has user-configurable operating modes and dual outputs with independent time settings. The Outputs can be configured for direct 12vdc-connected devices such as our available LEDs and Bells or can be configured as a dry contact relay to control other external devices. The included LED indication light on the rear panel allows you to see the current state or status of the alert controller.

The SA812 is our first pager-connected alert controller that offers standard screw terminal connections for both outputs and external input. The input allows you to interface items such as a manual activation button or a 2nd pager for mutual aid jurisdictions. These screw terminal connections make it easy to connect devices without a proprietary connector.

Relay K2 has two connections, one being on the rear of the controller and the other available on the inside of the controller housing. This secondary connection is designed to allow users to affix LEDs or other notification devices directly to the housing of the alert controller. 

The user selects all setting and times from inside the controller. These settings include the following operating modes and times:

Operating Modes:
1 - On any Trigger, both relays activate for dip-switch set time
2 - On Any Trigger K1 Delays activating for 1 Second, K2 No Delay activating.
3 -  On Any Trigger K1 Cycles 1 second on 1 second off for the duration of the time setting, K2 activates without any cycling.
4 - Input 1 Trigger Activates Relay K1 Only; 5-Pin DIN trigger Activates Relay K2 Only
5 - Input 1 Trigger Activates Relay K1 Only; 5-Pin Din Activates Both Relay K1 & K2
6 - Input 1 Trigger Activates Relay K2 Only; 5-Pin Din Activates Both Relay K1 & K2
7 - Input 1 Trigger Activates Both Relay K1 & K2; 5-Pin DIN Activates K1 Only
8 - Input 1 Trigger Activates Both Relay K1 & K2; 5-Pin DIN Activates K2 Only

Time Settings: (K1 and K2 Have Indepentent Times)
1 Seconds
3 Seconds
5 Seconds
10 Seconds
15 Seconds
30 Seconds
45 Seconds
1 Minute
3 Minutes
5 Minutes
10 Minutes
15 Minutes
30 Minutes
45Minutes

The SA812 is replacing the SA2, SA2+ & SA3 Controllers.